European Facility For Airborne Research

European Facility For Airborne Research March 28, 2024, 12:55

Instrument: RGB Multispectral camera Duncantech MS 4100

Name RGB Multispectral camera Duncantech MS 4100
Acronym RGB Multispectral camera
Manufacturer Duncantech
Operated by CNR-ISAFoM
Operated onboard

Instrument type

Name Imaging Spectrometer
Acronym Imaging Spectrometer

Principle of operation

Measured parameter Radiance Spectra
Operating principle

Measurement(s) Hyperspectral

Dimension and weight

External dimension 0.1*0.1*0.25 m
Weight 1.8

Performance

Operating mode Remote sensing
Range

Resolution

Sensitivity

Accuracy

Bandwidth

Modifications

Operational restriction

Operational requirements

Operating Voltage 12 VDC
Power Consumption 15 Watts

Certification approvals

Additional information

- Image output: Digital Image OutputCameraLink, EIA-644 (LVDS) or RS-422: 8 bits x 4 taps or 10 bits x 3 taps,

- Signal/Noise 60 dB
- Lens Mount Nikon Bayonet Mount
-Gain SelectionRange: 0-36 dB. Controlled via RS
- External Trigger Input Edge or level, three modes External Trigger Source BNC or Frame Grabber (Optical isolator on BNC)
- Exposure Control: Manual or Automatic
- White Balance: Manual or Semi
- Noise Reduction: Correlated Double Sampling
- Usability Features: Digital cross hairs, Color
- Operating Temperature 0-50 C
- Programmable Functions: Gain, exposure time, multiplexing, trigger, modes, custom processing
- DirectView Output: Progressive Scan RGB (1280x1024 max display resolution). Gamma correction.
2x and 4x digital zoom

Access, host and processing